10KW Three-Phase Distributed On-off Micro Grid System

Description

  • A commercial solar generator with intelligent CPU control technology and high-performance security
  • Pure sine wave output, with an output frequency of 50HZ, coincides with the mains. It also can be applied to any (not greater than the present maximum output power) loads, including motors, compressors, relays, fluorescent lamps, laser printers, impact drill and some non-analog sine wave and modified-sine wave inverter drive electrical equipment
  • Provides perfect protection function, including overload protection, overcurrent protection, high temperature protection, short circuit protection, reverse battery protection, battery level protection, and high and low mains voltage protection to make users feel safe and secure.
  •  Low noise output. There is no additional noise other than the low hum of the high-temperature radiator fan when it is in use.

*When the grid is disconnected or broken down, our system will work in Off-Grid mode. Under this mode, the unit will transfer solar power or electricity stored in the battery to AC in order to power all electricity needs.

*All power needs can be provided by our system. The unit will use battery storage to power the loads under normal capacity. If provided electricity is more than your need and the battery is fully charged, it will feedback excess electricity to the Grid.

*If the battery is low and sunshine is weak, the system will first check that battery capacity is sufficient, and then use the grid electricity to power loads.

Model Name                      MG3210K Distributed On-off Micro Grid System
Continuous Rated Power 10KW
AC Parameters
Rated Alternating Voltage Grid Voltage 400VAC
Inverter Voltage 400VAC
Rated AC Frequency 50Hz
Total Harmonic Distortion Grid Current <4%
Inverter Voltage 2%
On/off Grid Switching Time < 20ms
Maximum Inverter Efficency 93.80%
≥92%
Referenced Certification Standard CE,VDE 0126-1-1
Output Wave Pure Sine Wave
DC Parameters
Recommended Each line PV Input Power 4000W
PV Input 3 lines
Each PV Line Panels Start-up Maximum Voltage 145VDC(under definite lowest temperature condition)
MPPT Voltage Range 70~120VDC
PV Maximum Output Current 240A
Charger Maximum Efficiency 97.30%
Battery Voltage Rated Value 52VDC
Working Range 48~57VDC
System Parameters
Stored Capacity ≥30KWh
External Communications RS485(RS232/USB/Internet Optional)
Working Environment Temperature 0oC~45oC
Working Environment Humidity 10%~90%
Altitude <2000m
IP Grade IP54
Dimension Battery Box 1130mm×800mm×600mm
Inverter Box 1130mm×800mm×600mm
Weight Battery Box 240kg
Inverter Box 210kg